How much lubricant should be applied to my conveyor chain and trolleys

How much lubricant should be applied to my conveyor chain and trolleys

On enclosed track conveyors, typical lube time settings are around 10 to 15 milliseconds. Monorail and formed track conveyors require more because of the greater bearing surface to be covered, usually somewhere in the 15 to 25 millisecond range. Depending on various factors, these settings may be higher or lower, but it is not recommended to go below 8 milliseconds to insure proper solenoid operation